Knowledge tube furnace How do Ti/Al ratio and furnace temp affect GaN HEMT contact resistivity? Optimize your process recipe!
Author avatar

Tech Team · Kintek Furnace

Updated 3 months ago

How do Ti/Al ratio and furnace temp affect GaN HEMT contact resistivity? Optimize your process recipe!


The Ti/Al weight ratio and the peak furnace annealing temperature together define the sweet spot for minimum contact resistivity.

For Ti/Al-based ohmic contacts on GaN HEMTs, a leaner Ti content (Ti/Al = 30/70) enables optimum ohmic behavior at a furnace temperature of 800°C, yielding a contact resistivity as low as 3.47 × 10⁻⁵ Ω·cm². When the Ti fraction is raised to 70/30, the optimal furnace temperature shifts upward to 850°C. In all cases, exceeding the material‑specific optimal temperature degrades contact performance through out‑diffusion, oxidation, and surface roughening. The relationship is not linear, and precise control of both the metallization ratio and the furnace’s thermal uniformity is essential.

The Ti/Al ratio determines the temperature at which the contact forms the lowest‑resistance alloy. A 30/70 ratio achieves its best result at 800°C, while a 70/30 ratio needs 850°C. Regardless of ratio, pushing beyond the optimum furnace temperature spoils the contact with higher resistivity and poor morphology. The key is matching the initial stack composition to a tightly controlled furnace anneal.

The Interplay of Ti/Al Ratio and Furnace Temperature

The Ti/Al weight ratio is not a free variable. It chemically pre‑conditions how the multilayer stack reacts to heat. Together with the furnace’s thermal profile, it decides whether you get a low‑resistance ohmic contact or a degraded interface.

How the Ti/Al Ratio Redefines the Optimal Annealing Window

A 30/70 Ti/Al ratio (titanium‑lean) becomes ohmic at furnace temperatures as low as 700°C. It reaches its minimum contact resistivity of 3.47 × 10⁻⁵ Ω·cm² when annealed at 800°C using a Ti barrier. Even with a Mo barrier, the same ratio gives 7.46 × 10⁻⁵ Ω·cm² at 800°C. The Ti‑lean stack reacts earlier and delivers the lowest absolute values in the 800°C range.

A 70/30 Ti/Al ratio (titanium‑rich) demands a higher temperature. Its optimal furnace annealing temperature shifts to 850°C. The higher Ti fraction changes the alloying dynamics; more energy is needed to drive the interfacial reactions that form low‑resistance TiN and Al‑Ti intermetallics.

The Furnace’s Role: Uniform Heating and Atmosphere Control

The furnace is not just a heat source. A high‑temperature atmosphere furnace with a controlled gas (typically Ar + 1% H₂) provides the uniform heat distribution and reducing environment that prevent premature oxidation. Without this, even the perfect Ti/Al ratio will fail.

Temperature uniformity across the wafer is critical. Hotspots cause local over‑annealing, raising resistivity and roughening the surface. A tight furnace profile keeps the entire contact area inside the narrow optimal window defined by the Ti/Al ratio.

Why Exceeding the Optimal Temperature Hurts Performance

Over‑annealing triggers three destructive mechanisms. First, out‑diffusion of Ti and Al to the top Au layer removes the reactive metals from the semiconductor interface. Second, surface oxidation of the diffused metals creates resistive oxide layers. Third, enhanced mass transport leads to irregular surface morphology and edge‑balling, which increase sheet resistance and degrade reliability.

The optimal temperature is a cliff edge, not a plateau. Once you pass it, contact resistivity rises sharply. For the 30/70 ratio, moving beyond 800°C sends resistivity back up; for the 70/30 ratio, the threshold is 850°C.

Understanding the Trade‑offs and Pitfalls

Choosing a Ti/Al ratio and furnace recipe forces you to balance resistivity minimums against process latitude and barrier metal stability.

The Barrier Metal Influences Temperature Tolerance

Ti and Mo barriers behave differently. A Ti barrier (in Ti/Al/Ti/Au) can achieve the best‑in‑class 3.47 × 10⁻⁵ Ω·cm² at 800°C with the 30/70 ratio, but Mo barriers provide better high‑temperature stability with a slightly higher minimum (7.46 × 10⁻⁵ Ω·cm²). If your furnace control has minor excursions, Mo may offer a wider process window at the cost of a slightly higher floor.

Process Latitude vs. Lowest Resistivity

A Ti‑lean 30/70 stack gives lower absolute resistivity, but its optimal temperature is lower (800°C). This narrows the process margin if your furnace has overshoot tendencies. The Ti‑rich 70/30 stack shifts the optimum to 850°C, potentially offering a more robust window in furnaces that run hot, but with a resistivity penalty compared to the Ti‑lean design.

Furnace ramp rates also matter. Rapid heating can create transient temperature spikes that breach the optimal point even if the soak temperature is correct. Slow, controlled ramping helps the alloy reactions complete uniformly.

Hidden Sensitivity: Initial Metal Purity and Deposition

All published optimums assume high‑purity metals and clean interfaces. Impurities or interfacial oxide before annealing shift the reaction kinetics, effectively moving the optimal temperature. Your furnace must be re‑calibrated to your specific deposition tool and metal stack.

Making the Right Choice for Your Goal

The answer to “which ratio and what temperature” depends on what you prioritize most.

  • If your primary focus is the absolute lowest contact resistivity: Adopt the Ti/Al = 30/70 weight ratio and target a furnace anneal at 800°C with a Ti barrier, using a tightly controlled Ar/H₂ atmosphere.
  • If your primary focus is process resilience against temperature overshoot: Consider a 70/30 Ti/Al ratio with an 850°C furnace target; the higher thermal threshold gives more headroom if your furnace uniformity is less than perfect.
  • If your primary focus is long‑term reliability and smooth morphology: Use a Mo barrier with the 30/70 Ti/Al ratio at 800°C. The slightly higher resistivity (7.46 × 10⁻⁵ Ω·cm²) buys superior surface quality and resistance to over‑annealing damage.
  • If your primary focus is low‑thermal‑budget integration: The 30/70 ratio can start becoming ohmic as low as 700°C, usable if you can accept non‑minimal contact resistivity.

Match the metallization design to your furnace’s real‑world temperature control, and you can consistently hit the sweet spot that your specific Ti/Al stack demands.

Summary Table:

| Ti/Al Ratio | Barrier Metal | Optimal Annealing Temp | Min. Contact Resistivity | Key Characteristics &

Advantages
30/70 (Ti-Lean)
30/70 (Ti-Lean)
70/30 (Ti-Rich)

Achieve Precise Thermal Profiles for Your GaN Semiconductor Process

Optimizing Ti/Al ohmic contacts requires uncompromising temperature uniformity and precise gas atmosphere control. KINTEK specializes in advanced laboratory equipment and consumables, offering a comprehensive range of customizable high-temperature furnaces—including high-precision atmosphere furnaces, tube furnaces, vacuum furnaces, and muffle furnaces—engineered to meet the exact thermal demands of semiconductor fabrication.

Whether you need reliable thermal profiles to eliminate contact out-diffusion or custom furnace configurations for specialized recipes, KINTEK delivers high-performance solutions designed to maximize your process yield and research reproducibility.

Contact KINTEK today to upgrade your lab's thermal processing capabilities!

Related Products

People Also Ask

Related Products

1700℃ Controlled Inert Nitrogen Atmosphere Furnace

1700℃ Controlled Inert Nitrogen Atmosphere Furnace

KT-17A Controlled Atmosphere Furnace: Precise 1700°C heating with vacuum & gas control. Ideal for sintering, research & material processing. Explore now!

1400℃ High Temperature Laboratory Tube Furnace with Alumina Tube

1400℃ High Temperature Laboratory Tube Furnace with Alumina Tube

KINTEK's Tube Furnace with Alumina Tube: Precision high-temperature processing up to 2000°C for labs. Ideal for material synthesis, CVD, and sintering. Customizable options available.

1800℃ High Temperature Muffle Oven Furnace for Laboratory

1800℃ High Temperature Muffle Oven Furnace for Laboratory

KINTEK Muffle Furnaces: Precision 1800°C heating for labs. Energy-efficient, customizable, with PID control. Ideal for sintering, annealing, and research.

2200 ℃ Tungsten Vacuum Heat Treat and Sintering Furnace

2200 ℃ Tungsten Vacuum Heat Treat and Sintering Furnace

2200°C Tungsten Vacuum Furnace for high-temperature materials processing. Precise control, superior vacuum, customizable solutions. Ideal for research & industrial applications.

2200 ℃ Graphite Vacuum Heat Treat Furnace

2200 ℃ Graphite Vacuum Heat Treat Furnace

2200℃ Graphite Vacuum Furnace for high-temperature sintering. Precise PID control, 6*10⁻³Pa vacuum, durable graphite heating. Ideal for research & production.

1700℃ High Temperature Laboratory Tube Furnace with Alumina Tube

1700℃ High Temperature Laboratory Tube Furnace with Alumina Tube

KINTEK's Tube Furnace with Alumina Tube: Precision heating up to 1700°C for material synthesis, CVD, and sintering. Compact, customizable, and vacuum-ready. Explore now!

Laboratory Muffle Oven Furnace with Bottom Lifting

Laboratory Muffle Oven Furnace with Bottom Lifting

Boost lab efficiency with KT-BL Bottom Lifting Furnace: precise 1600℃ control, superior uniformity, and enhanced productivity for material science and R&D.

1700℃ High Temperature Muffle Oven Furnace for Laboratory

1700℃ High Temperature Muffle Oven Furnace for Laboratory

KT-17M Muffle Furnace: High-precision 1700°C lab furnace with PID control, energy efficiency, and customizable sizes for industrial & research applications.

1200℃ Split Tube Furnace Laboratory Quartz Tube Furnace with Quartz Tube

1200℃ Split Tube Furnace Laboratory Quartz Tube Furnace with Quartz Tube

Discover KINTEK's 1200℃ Split Tube Furnace with quartz tube for precise high-temperature lab applications. Customizable, durable, and efficient. Get yours now!

1200℃ Controlled Inert Nitrogen Atmosphere Furnace

1200℃ Controlled Inert Nitrogen Atmosphere Furnace

KINTEK 1200℃ Controlled Atmosphere Furnace: Precision heating with gas control for labs. Ideal for sintering, annealing, and material research. Customizable sizes available.

1200℃ Muffle Oven Furnace for Laboratory

1200℃ Muffle Oven Furnace for Laboratory

KINTEK KT-12M Muffle Furnace: Precision 1200°C heating with PID control. Ideal for labs needing rapid, uniform heat. Explore models & customization options.

1400℃ Muffle Oven Furnace for Laboratory

1400℃ Muffle Oven Furnace for Laboratory

KT-14M Muffle Furnace: Precision 1400°C heating with SiC elements, PID control, and energy-efficient design. Ideal for labs.

Controlled Inert Nitrogen Hydrogen Atmosphere Furnace

Controlled Inert Nitrogen Hydrogen Atmosphere Furnace

Discover KINTEK's Hydrogen Atmosphere Furnace for precise sintering & annealing in controlled environments. Up to 1600°C, safety features, customizable.

High Temperature Muffle Oven Furnace for Laboratory Debinding and Pre Sintering

High Temperature Muffle Oven Furnace for Laboratory Debinding and Pre Sintering

KT-MD Debinding & Pre-Sintering Furnace for ceramics - precise temperature control, energy-efficient design, customizable sizes. Boost your lab efficiency today!

Vertical Laboratory Quartz Tube Furnace Tubular Furnace

Vertical Laboratory Quartz Tube Furnace Tubular Furnace

Precision KINTEK Vertical Tube Furnace: 1800℃ heating, PID control, customizable for labs. Ideal for CVD, crystal growth & materials testing.

Vacuum Heat Treat Sintering Furnace Molybdenum Wire Vacuum Sintering Furnace

Vacuum Heat Treat Sintering Furnace Molybdenum Wire Vacuum Sintering Furnace

KINTEK's Vacuum Molybdenum Wire Sintering Furnace excels in high-temperature, high-vacuum processes for sintering, annealing, and material research. Achieve precise 1700°C heating with uniform results. Custom solutions available.


Leave Your Message